Home / Benchmarking laws / Philadelphia
Philadelphia, PA · Reviewed November 2026

Philadelphia benchmarking compliance, filed for you

Philadelphia Building Energy Benchmarking + Building Energy Performance Policy requires covered buildings in Philadelphia to report energy and water use every year. We gather the data, check it, and file it — usually within a week.

Who’s covered

Commercial, multifamily and public buildings with more than 50,000 sq ft of indoor floor area.

Annual deadline

June 30 for the previous calendar year.

Verification

No routine third-party verification — but the city runs its own data checks, so accuracy still matters.

Penalties

$300 for the first month late, then $100 for each additional day.

What are Philadelphia’s building energy requirements?

Philadelphia has two building energy laws run by the Office of Sustainability. The Building Energy Benchmarking Ordinance (2012) requires large buildings to report a year of energy and water use through ENERGY STAR Portfolio Manager by June 30 each year. Tenants are required to provide their usage data to owners on request.

The Building Energy Performance Policy (2019), carried out through the Building Energy Performance Program (BEPP), requires non-residential buildings of 50,000 sq ft or more to complete a building tune-up every five years — or show the building is already a high performer. A tune-up is a review of energy systems and controls by a certified specialist, followed by required corrective actions.

Benchmarking compliance also matters for BEPP: to qualify as a high-performance building, you need a clean benchmarking record in the years before your tune-up deadline.

Key dates

January–MarchCollect last year’s bills; request whole-building data from PECO and PGW
June 30Annual benchmarking report due for the previous calendar year
Sept 30, 2026Tune-up or high-performance report: buildings over 200,000 sq ft
Sept 30, 2027Tune-up or high-performance report: 100,000–200,000 sq ft
Oct 2, 2028Tune-up or high-performance report: 70,000–100,000 sq ft
Oct 1, 2029Tune-up or high-performance report: 50,000–70,000 sq ft

Tune-up dates are the city’s second five-year cycle. We confirm current dates with the Office of Sustainability before every filing.

Is your building covered?

Benchmarking applies to commercial, multifamily and public buildings with more than 50,000 sq ft of indoor floor space, including multiple buildings on one lot that add up to that size.

Building tune-ups (BEPP) apply to non-residential buildings of 50,000 sq ft or more, with deadlines staggered by size. Buildings can comply in three ways: complete a tune-up, certify as a high-performance building (for example, with ENERGY STAR certification), or obtain an exemption — such as when the building is scheduled for demolition within a year of its deadline.

What to report

All energy and water used by the whole building — including tenant spaces — for January 1 to December 31:

  • Electricity — every meter serving the building
  • Natural gas
  • District steam, hot or chilled water, if you have it
  • Delivered fuels (oil, diesel, propane) — all delivery receipts for the year
  • On-site solar production, if any
  • Water — whole-building water use

Leave out backup generator fuel. Note any meters added or removed during the year.

Good to know

  • Non-residential buildings over 50,000 sq ft must also complete a building tune-up (or show high performance); the next cycle starts in 2026.

What we’ll need from you

  • Building address, plus any utility service addresses that differ from it
  • Gross floor area for the whole building and each use (office, retail, residential…), number of units and year built
  • Your Philadelphia Building ID / OPA account (we can look it up)
  • Utility data for the full calendar year, January 1 – December 31 (usually 13 months of bills)
  • If tenants pay their own utilities: whole-building (aggregated) data from the utility, or signed tenant authorization forms
  • Access to your ENERGY STAR Portfolio Manager account, if you have one
  • Any notice or letter you received from the city
Step by step

How to comply

  1. Confirm your building’s statusCheck the city’s covered buildings list and your Philadelphia benchmarking and BEPP IDs.
  2. Set up Portfolio ManagerEnter gross floor area, property uses and details, and add the city’s required building ID.
  3. Collect whole-building energy and water dataRequest data from PECO (electric) and PGW (gas), plus Vicinity steam, delivered fuels and Philadelphia Water Department data. Ask tenants for their usage where needed — they’re required to share it.
  4. Check data qualityFix gaps and outliers before submitting.
  5. Submit by June 30Send the report to the city through Portfolio Manager and keep the confirmation.
  6. Plan your five-year tune-upBefore your BEPP deadline, decide whether to certify as high performance or complete a tune-up with a certified specialist (a PE or CEM).

Philadelphia building tune-ups (BEPP)

Tune-up

A certified tune-up specialist reviews HVAC, lighting, controls and other systems, the owner makes required corrections, and the specialist submits the tune-up report.

High-performance certification

Buildings that meet a performance threshold — such as ENERGY STAR certification — and have been compliant with benchmarking can certify instead of doing a tune-up.

Penalties

Missing a BEPP deadline brings a $2,000 fine, then $500 per day after the first 30 days until the building complies.

Exemptions and extensions

For BEPP, the city opens windows to request an extension, file for an exemption or submit an Alternative Compliance Plan several months before each size group’s deadline. Exemptions include buildings scheduled for demolition within one year of the deadline.

For benchmarking, file as close to June 30 as you can: buildings that are late receive a $300 fine after the first 30 days, then $100 per day until the report is submitted.

If the city’s records show the wrong size or use for your building, ask the Office of Sustainability to correct them before your deadline.

Common mistakes we fix

  • Leaving out tenant-paid PECO meters when tenants are required to share data
  • Missing the Philadelphia building ID in Portfolio Manager
  • Forgetting that water data is required
  • Missing the window to request a BEPP extension or exemption
  • Assuming ENERGY STAR certification alone qualifies as high performance without clean benchmarking compliance
  • Using a tune-up specialist who isn’t certified by the city for that year

How 1st Green Choice helps

We file Philadelphia benchmarking reports for offices, multifamily and condo buildings, hospitals, universities, hotels and retail. We request whole-building data from PECO and PGW, collect tenant data where needed, set up or correct Portfolio Manager and submit by June 30.

When your BEPP deadline approaches, we’ll check whether your building can certify as high performance — which saves the cost of a tune-up — and keep your benchmarking record clean so that option stays open.

FAQ

Philadelphia benchmarking questions

When is the Philadelphia benchmarking deadline?
June 30 each year for the previous calendar year’s energy and water use.
Which buildings must benchmark in Philadelphia?
Commercial, multifamily and public buildings with more than 50,000 square feet of indoor floor space.
What is the penalty for late benchmarking in Philadelphia?
A $300 fine after the first 30 days past the deadline, then $100 per day until the report is submitted.
What is the Philadelphia building tune-up requirement?
Under the Building Energy Performance Policy, non-residential buildings of 50,000+ sq ft must complete a tune-up of building systems every five years, certify as high performance, or obtain an exemption.
When is my Philadelphia tune-up due?
In the second cycle: September 30, 2026 for buildings over 200,000 sq ft; September 30, 2027 for 100,000–200,000 sq ft; October 2, 2028 for 70,000–100,000 sq ft; and October 1, 2029 for 50,000–70,000 sq ft.
Who can perform a Philadelphia tune-up?
A tune-up specialist certified by the city, who must hold a Professional Engineer (PE) or Certified Energy Manager (CEM) credential.
What are the penalties for missing a tune-up?
A $2,000 fine, then $500 per day after the first 30 days until the building complies.
Do tenants have to share energy data in Philadelphia?
Yes. Tenants are required to provide their energy and water usage to the building owner on request so the owner can benchmark the whole building.