Washington State · Reviewed November 2026

Washington Clean Buildings compliance, filed for you

The Washington Clean Buildings Performance Standard requires covered buildings to report energy use every year. We gather the data, check it, and file it — usually within a week.

Who’s covered

Commercial buildings over 20,000 sq ft and multifamily buildings, phased in by size from 2026 to 2028 (largest buildings first).

Annual deadline

June 1 for the previous calendar year. Your first year depends on size: over 220,000 sq ft from 2026, 90,001–220,000 sq ft from 2027, 50,000–90,000 sq ft from 2028.

Verification

No routine third-party verification — but the program runs its own data checks, so accuracy still matters.

Penalties

Up to $5,000 plus $1 per sq ft per year for missing performance requirements.

What is the Washington Clean Buildings Performance Standard?

Washington’s Clean Buildings Performance Standard (CBPS), created by the Clean Buildings Act (HB 1257, 2019) and expanded in 2022, is run by the Washington State Department of Commerce and based on ASHRAE Standard 100. It is an energy performance standard: buildings are measured by their energy use intensity (EUI) against a target for their type.

Buildings fall into two tiers. Tier 1 — non-residential buildings over 50,000 sq ft — must benchmark, adopt an energy management plan and an operations and maintenance program, and either meet their EUI target or follow the investment criteria by completing an energy audit and cost-effective upgrades. Tier 2 — non-residential buildings of 20,001–50,000 sq ft and all multifamily over 20,000 sq ft — must benchmark and adopt an energy management plan and O&M program.

Compliance repeats every five years after a building’s first deadline. The state offers early-adopter incentives for buildings that improve before they’re required to.

Key dates

June 1, 2026Tier 1 compliance: buildings over 220,000 sq ft
June 1, 2027Tier 1 compliance: 90,001–220,000 sq ft
July 1, 2027Tier 2 reporting: 20,001–50,000 sq ft and all multifamily over 20,000 sq ft
June 1, 2028Tier 1 compliance: 50,001–90,000 sq ft
Every 5 yearsEach building repeats compliance after its first deadline

Commerce is updating its rules through 2026 rulemaking. We confirm current requirements and dates before every filing.

Is your building covered?

Tier 1: non-residential buildings with more than 50,000 sq ft of floor area, excluding parking.

Tier 2: non-residential buildings of 20,001–50,000 sq ft, and multifamily residential buildings over 20,000 sq ft.

Campuses can comply together under certain conditions. Federal buildings and buildings owned exclusively by federally recognized tribes are not covered. Buildings in Seattle must also meet the city’s benchmarking and BEPS rules.

What to report

All energy used by the whole building — including tenant spaces — for January 1 to December 31:

  • Electricity — every meter serving the building
  • Natural gas
  • District steam, hot or chilled water, if you have it
  • Delivered fuels (oil, diesel, propane) — all delivery receipts for the year
  • On-site solar production, if any

Leave out backup generator fuel. Note any meters added or removed during the year.

Good to know

  • Larger buildings must also keep an energy management plan and meet an energy use intensity target.
  • Seattle buildings report to Seattle’s program as well.

What we’ll need from you

  • Building address, plus any utility service addresses that differ from it
  • Gross floor area for the whole building and each use (office, retail, residential…), number of units and year built
  • Your Washington Clean Buildings ID (we can look it up)
  • Utility data for the full calendar year, January 1 – December 31 (usually 13 months of bills)
  • If tenants pay their own utilities: whole-building (aggregated) data from the utility, or signed tenant authorization forms
  • Access to your ENERGY STAR Portfolio Manager account, if you have one
  • Any notice or letter you received about this law
Step by step

How to comply

  1. Confirm your tier and deadlineCheck Commerce’s covered buildings list and notification letter for your tier and compliance date.
  2. Benchmark in Portfolio ManagerEnter at least 12 consecutive months of whole-building energy data.
  3. Calculate your EUI targetTier 1 buildings determine their target (EUIt) from property type and operating hours.
  4. Adopt an energy management plan and O&M programBoth are required for Tier 1 and Tier 2 buildings.
  5. Meet the target or follow the investment criteriaIf above the target, complete an energy audit and implement cost-effective measures.
  6. Submit your compliance reportFile through the state’s portal by your deadline, with documentation reviewed by a qualified energy manager where required.

Tier 1 vs. Tier 2

Tier 1 (over 50,000 sq ft)

Benchmarking, energy management plan, O&M program, and meet the EUI target or the investment criteria.

Tier 2 (20,001–50,000 sq ft and multifamily)

Benchmarking, energy management plan and O&M program — no EUI target requirement at this stage.

Penalties

Tier 1 buildings that don’t comply face penalties of up to $5,000 plus a per-square-foot amount; Tier 2 penalties are smaller and also based on floor area.

Exemptions and extensions

Commerce allows extensions and exemptions in specific situations — for example, financial hardship, low occupancy, recent major renovation or pending demolition. Requests must be submitted before your compliance date with supporting documentation.

Early-adopter incentives are available to Tier 1 buildings that reduce energy use below their target before their deadline, and to Tier 2 buildings that act early.

Common mistakes we fix

  • Using the wrong property type or operating hours, which changes the EUI target
  • Benchmarking fewer than 12 consecutive months of data
  • Skipping the energy management plan or O&M program
  • Assuming Seattle benchmarking covers state compliance — both are required
  • Waiting until the last year to start an energy audit if the building is above target

How 1st Green Choice helps

We benchmark Washington buildings for both tiers, calculate EUI targets, and prepare the documentation Commerce requires. For Tier 1 buildings above their target, our in-house professional engineers can coordinate the audit and investment-criteria path.

FAQ

Washington Clean Buildings questions

When are Washington Clean Buildings deadlines?
Tier 1: June 1, 2026 for buildings over 220,000 sq ft, June 1, 2027 for 90,001–220,000 sq ft, and June 1, 2028 for 50,001–90,000 sq ft. Tier 2: July 1, 2027.
What is the difference between Tier 1 and Tier 2?
Tier 1 is non-residential over 50,000 sq ft and must meet an EUI target or investment criteria. Tier 2 is 20,001–50,000 sq ft non-residential and multifamily over 20,000 sq ft, with benchmarking, an energy management plan and an O&M program.
What is an EUI target?
The energy use intensity your building must reach, based on its property type and operating hours, measured in kBtu per square foot per year.
What if my building doesn’t meet its EUI target?
You can comply through the investment criteria: complete an energy audit and implement cost-effective energy efficiency measures.
What are the penalties?
Tier 1 penalties can reach $5,000 plus a per-square-foot amount for each compliance cycle; Tier 2 penalties are smaller and based on floor area.
How often do I have to comply?
Every five years after your first compliance date.
Are there incentives?
Yes. The state offers early-adopter incentives for buildings that improve before their deadline.
Do Seattle buildings have to comply too?
Yes. Seattle buildings must meet both the state standard and the city’s benchmarking and BEPS requirements.

Official sources: Washington Department of Commerce — Clean Buildings Performance Standard. Requirements change — we confirm current rules for every filing.