SF Existing Buildings Ordinance compliance, filed for you
Existing Buildings Energy Performance Ordinance (Environment Code Chapter 20) requires covered buildings in San Francisco to report energy use every year. We gather the data, check it, and file it — usually within a week.
Who’s covered
Non-residential buildings of 10,000 sq ft or more and residential buildings of 50,000 sq ft or more.
Annual deadline
May 1 for the previous calendar year.
Verification
No routine third-party verification — but the city runs its own data checks, so accuracy still matters.
Penalties
$100 per day for buildings over 50,000 sq ft and $50 per day for smaller buildings (up to 25 days).
What is San Francisco’s Existing Buildings Ordinance?
San Francisco’s Existing Buildings Energy Performance Ordinance (Environment Code Chapter 20), adopted in 2011, has two parts. Every covered building must benchmark its energy use in ENERGY STAR Portfolio Manager and report it to SF Environment each year. Non-residential buildings must also complete an energy audit, retro-commissioning or Strategic Decarbonization Assessment at least once every five years.
Benchmarking results are published on the city’s open data portal, along with each building’s compliance status.
A practical benefit: SF Environment shares your benchmarking report with the state, so filing in San Francisco also satisfies California AB 802 for the same building — one submission, two laws.
Key dates
| January–March | Collect last year’s bills; request aggregated data from PG&E and your electricity provider |
| May 1 | Annual benchmark due for the previous calendar year (May 1, 2026 for 2025 data) |
| Every 5 years | Energy audit, retro-commissioning or Strategic Decarbonization Assessment for non-residential buildings, on the building’s assigned cycle |
| Ongoing | Largest commercial buildings must source 100% renewable electricity under a separate ordinance |
We confirm the current deadline and your building’s audit year with SF Environment before every filing.
Is your building covered?
The ordinance applies to buildings in San Francisco with:
- 10,000 sq ft or more of conditioned space in non-residential use — annual benchmarking plus an audit every five years.
- 50,000 sq ft or more in residential use — annual benchmarking.
SF Environment publishes a compliance lookup where you can check your building’s status by address or parcel. Mixed-use buildings follow the requirements for their non-residential area.
What to report
All energy used by the whole building — including tenant spaces — for January 1 to December 31:
- Electricity — every meter serving the building
- Natural gas
- District steam, hot or chilled water, if you have it
- Delivered fuels (oil, diesel, propane) — all delivery receipts for the year
- On-site solar production, if any
- Water — we’ll confirm whether it’s required for your building
Leave out backup generator fuel. Note any meters added or removed during the year.
Good to know
- Commercial buildings also need an energy audit every five years.
- Buildings that report to San Francisco don’t have to file separately under California’s AB 802.
- Large commercial buildings face a 100% renewable electricity requirement.
What we’ll need from you
- Building address, plus any utility service addresses that differ from it
- Gross floor area for the whole building and each use (office, retail, residential…), number of units and year built
- Your Block / Lot number (we can look it up)
- Utility data for the full calendar year, January 1 – December 31 (usually 13 months of bills)
- If tenants pay their own utilities: whole-building (aggregated) data from the utility, or signed tenant authorization forms
- Access to your ENERGY STAR Portfolio Manager account, if you have one
- Any notice or letter you received from the city
How to comply
- Check your building’s statusUse SF Environment’s compliance lookup to confirm coverage, your benchmark status and your next audit year.
- Set up Portfolio ManagerEnter floor area, property uses and details, and add the city’s Parcel number (Block/Lot) so the report can be matched.
- Collect whole-building dataRequest aggregated data from PG&E, and from CleanPowerSF or your other electricity provider; add steam from district systems if you have it.
- Check data qualityFix gaps and outliers so your published results are accurate.
- Submit by May 1Send the report to SF Environment through Portfolio Manager. It also satisfies the state’s AB 802 benchmarking.
- Complete your five-year audit when dueHave a qualified professional perform an energy audit, retro-commissioning or Strategic Decarbonization Assessment and submit the report.
Other San Francisco requirements
Five-year energy audits
Non-residential buildings complete an energy audit, retro-commissioning or Strategic Decarbonization Assessment at least every five years, on an assigned cycle.
High-performer exemptions
Buildings that demonstrate high performance — for example, recent ENERGY STAR certification — may qualify for an exemption from the audit for that cycle.
100% renewable electricity
A separate ordinance requires the largest commercial buildings to get all of their electricity from renewable sources through a qualifying service.
Exemptions and extensions
Newly constructed buildings are exempt until they have enough operating history to benchmark. High-performing buildings may be exempt from the five-year audit — ask us whether yours qualifies.
If you can’t meet the deadline, contact SF Environment before May 1 to discuss your situation. Buildings that don’t comply first receive a warning, then a public notice of non-compliance, and then fines.
If the city’s records list the wrong floor area or use for your building, request a correction so your obligations match the actual building.
Common mistakes we fix
- Missing the Parcel number in Portfolio Manager, so the report isn’t matched to the building
- Filing separately with the state for AB 802 when the San Francisco report already covers it
- Leaving out tenant-paid PG&E or CleanPowerSF meters
- Forgetting the five-year audit year until the benchmark is filed
- Hiring an auditor who isn’t qualified under the ordinance
- Not checking whether the building qualifies for a high-performer audit exemption
How 1st Green Choice helps
We file San Francisco benchmarks for offices, retail, hotels, multifamily and mixed-use buildings. We confirm your status and audit year, request whole-building data from PG&E and your electricity provider, set up or correct Portfolio Manager and submit by May 1 — which also takes care of your AB 802 filing.
When your five-year audit is due, we’ll tell you which options fit your building and coordinate the work so it’s submitted on time.
SF Existing Buildings Ordinance questions
When is the San Francisco benchmarking deadline?
Which San Francisco buildings must benchmark?
How often is an energy audit required in San Francisco?
Does the San Francisco report count for California AB 802?
What happens if I don’t comply?
Can a building be exempt from the audit?
What is a Strategic Decarbonization Assessment?
Is water benchmarking required in San Francisco?
Official sources: SF Environment — Existing Buildings Energy Performance Ordinance. Requirements change — we confirm current rules for every filing.